{"_buckets": {"deposit": "b086c6b5-25b1-45d9-a4de-1dfc3f40d841"}, "_deposit": {"created_by": 1, "id": "11123", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "11123"}, "status": "published"}, "_oai": {"id": "oai:kansai-u.repo.nii.ac.jp:00011123", "sets": ["1591"]}, "author_link": ["24122", "24121", "24124", "24129", "24120", "24123", "24125", "24126", "24127", "24128"], "item_9_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-05-15", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "213", "bibliographicPageStart": "207", "bibliographicVolumeNumber": "47", "bibliographic_titles": [{"bibliographic_title": "JSME international journal. Ser. B, Fluids and thermal engineering"}]}]}, "item_9_description_4": {"attribute_name": "概要", "attribute_value_mlt": [{"subitem_description": "An advanced-type compact water-tube boiler has been designed on the basis of the new concept of cooling flame by water-tube bank in the furnace, and is referred to as \"tube-nested combustor\". It realized drastic reduction in boiler size as well as in the NO_x emission. In this present study, aiming at further improvement of boiler efficiency and reduction of NO_x emission, the combustion characteristics in the furnace were investigated by using the test boiler of 0.5t/h steam output. Experimental results indicated that the NO_x formation was restricted in the narrow area close to the burner exit, and that the CO-concentration decreased drastically with the combustion gas stream through the tube-bank. These facts were closely related to the experimental evidence of the cross-sectional distribution of gas temperature being rather uniform owing to the agitation by the tube-bank. These experimental results verified the soundness of the boiler design and, in addition, gave relevant information on local combustion characteristics available for the R\u0026D of the next generation tube-nested combustor.", "subitem_description_type": "Other"}]}, "item_9_description_42": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_9_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "24125", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "世古, 哲嗣"}]}, {"nameIdentifiers": [{"nameIdentifier": "24126", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "松本, 亮介"}]}, {"nameIdentifiers": [{"nameIdentifier": "24127", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "新谷, 喜智"}]}, {"nameIdentifiers": [{"nameIdentifier": "24128", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "石原, 勲"}]}, {"nameIdentifiers": [{"nameIdentifier": "24129", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "小澤, 守"}]}]}, "item_9_publisher_34": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Japan Society of Mechanical Engineers"}]}, "item_9_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1299/jsmeb.47.207", "subitem_relation_type_select": "DOI"}}]}, "item_9_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10888815", "subitem_source_identifier_type": "NCID"}]}, "item_9_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13408054", "subitem_source_identifier_type": "ISSN"}]}, "item_9_text_35": {"attribute_name": "出版者(他言語)", "attribute_value_mlt": [{"subitem_text_value": "日本機械学会"}]}, "item_9_version_type_17": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Seko, Tetsuji"}], "nameIdentifiers": [{"nameIdentifier": "24120", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsumoto, Ryosuke"}], "nameIdentifiers": [{"nameIdentifier": "24121", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50268314", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000050268314"}]}, {"creatorNames": [{"creatorName": "Shintani, Yoshitomo"}], "nameIdentifiers": [{"nameIdentifier": "24122", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishihara, Isao"}], "nameIdentifiers": [{"nameIdentifier": "24123", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30067657", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000030067657"}]}, {"creatorNames": [{"creatorName": "Ozawa, Mamoru"}], "nameIdentifiers": [{"nameIdentifier": "24124", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-05-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KU-1100-20040515-1.pdf", "filesize": [{"value": "994.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 994900.0, "url": {"label": "KU-1100-20040515-1.pdf", "url": "https://kansai-u.repo.nii.ac.jp/record/11123/files/KU-1100-20040515-1.pdf"}, "version_id": "9233c137-eeed-4038-b781-cf98cad7370c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Tube-Nested Combustor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Low NO", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Emission", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Diffusion Combustion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Combustion Characteristics", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Diffusion Combustion in a Tube-Nested Combustor", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Diffusion Combustion in a Tube-Nested Combustor"}]}, "item_type_id": "9", "owner": "1", "path": ["1591"], "permalink_uri": "http://hdl.handle.net/10112/4603", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-07-13"}, "publish_date": "2011-07-13", "publish_status": "0", "recid": "11123", "relation": {}, "relation_version_is_last": true, "title": ["Diffusion Combustion in a Tube-Nested Combustor"], "weko_shared_id": 1}
Diffusion Combustion in a Tube-Nested Combustor
http://hdl.handle.net/10112/4603
http://hdl.handle.net/10112/460396075360-c076-4c35-969c-547e50b65a21
名前 / ファイル | ライセンス | アクション |
---|---|---|
KU-1100-20040515-1.pdf (994.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-07-13 | |||||
タイトル | ||||||
タイトル | Diffusion Combustion in a Tube-Nested Combustor | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Seko, Tetsuji
× Seko, Tetsuji× Matsumoto, Ryosuke× Shintani, Yoshitomo× Ishihara, Isao× Ozawa, Mamoru |
|||||
著者別名 | ||||||
姓名 | 世古, 哲嗣 | |||||
著者別名 | ||||||
姓名 | 松本, 亮介 | |||||
著者別名 | ||||||
姓名 | 新谷, 喜智 | |||||
著者別名 | ||||||
姓名 | 石原, 勲 | |||||
著者別名 | ||||||
姓名 | 小澤, 守 | |||||
概要 | ||||||
内容記述タイプ | Other | |||||
内容記述 | An advanced-type compact water-tube boiler has been designed on the basis of the new concept of cooling flame by water-tube bank in the furnace, and is referred to as "tube-nested combustor". It realized drastic reduction in boiler size as well as in the NO_x emission. In this present study, aiming at further improvement of boiler efficiency and reduction of NO_x emission, the combustion characteristics in the furnace were investigated by using the test boiler of 0.5t/h steam output. Experimental results indicated that the NO_x formation was restricted in the narrow area close to the burner exit, and that the CO-concentration decreased drastically with the combustion gas stream through the tube-bank. These facts were closely related to the experimental evidence of the cross-sectional distribution of gas temperature being rather uniform owing to the agitation by the tube-bank. These experimental results verified the soundness of the boiler design and, in addition, gave relevant information on local combustion characteristics available for the R&D of the next generation tube-nested combustor. | |||||
書誌情報 |
JSME international journal. Ser. B, Fluids and thermal engineering 巻 47, 号 2, p. 207-213, 発行日 2004-05-15 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13408054 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10888815 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1299/jsmeb.47.207 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | Japan Society of Mechanical Engineers | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Tube-Nested Combustor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Low NO | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Emission | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Diffusion Combustion | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Combustion Characteristics | |||||
出版者(他言語) | ||||||
日本機械学会 |