{"created":"2023-05-15T12:20:49.540952+00:00","id":11528,"links":{},"metadata":{"_buckets":{"deposit":"ff9bf407-5623-4e34-a9d7-3a64eca91e36"},"_deposit":{"created_by":1,"id":"11528","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"11528"},"status":"published"},"_oai":{"id":"oai:kansai-u.repo.nii.ac.jp:00011528","sets":["528:1588:1595:1597"]},"author_link":["26969","26972","26968","26974","26973","26975","26970","26971"],"item_9_alternative_title_20":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"ESI-MS Analysis of Effluents from Medical Silicon Rubber"}]},"item_9_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2000","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"356","bibliographicPageStart":"353","bibliographicVolumeNumber":"48","bibliographic_titles":[{"bibliographic_title":"Journal of the Mass Spectrometry Society of Japan"}]}]},"item_9_description_4":{"attribute_name":"概要","attribute_value_mlt":[{"subitem_description":"The catheter tubes of medical silicon rubber were dipped in ethanol. The effluents were fractionated by thin-layer chromatography (TLC), and their fractions were analyzed by ion trap electrospray ionization mass spectrometry (ESI-MS). The ESI mass spectra resulting from the main TLC fraction, R1=0.5 showed that the effluents were determined to be poly(dimethyl siloxane) (8 to 20 mer) that is a main part of a silicon rubber. The spectra for the origin in TLC showed that poly(ethylene glycol) (4 to 10 mer and 14 to 18 mer) and poly- (propylene glycol) (19 to 36 mer) as an antistatic agent were identified.","subitem_description_type":"Other"}]},"item_9_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"26972","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Arakawa, Ryuichi"}]},{"nameIdentifiers":[{"nameIdentifier":"26973","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Fukuo, Tsuyoshi"}]},{"nameIdentifiers":[{"nameIdentifier":"26974","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kubota, Naoko"}]},{"nameIdentifiers":[{"nameIdentifier":"26975","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tamura, Masahiro"}]}]},"item_9_publisher_34":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Mass Spectrometry Society of Japan"}]},"item_9_source_id_10":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA1254271X","subitem_source_identifier_type":"NCID"}]},"item_9_source_id_8":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13408097","subitem_source_identifier_type":"ISSN"}]},"item_9_text_35":{"attribute_name":"出版者(他言語)","attribute_value_mlt":[{"subitem_text_value":"日本質量分析学会"}]},"item_9_version_type_17":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"荒川, 隆一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"福尾, 剛志"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"久保田, 直子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田村, 正博"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-05-23"}],"displaytype":"detail","filename":"KU-1100-20000000-11.pdf","filesize":[{"value":"391.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"KU-1100-20000000-11.pdf","url":"https://kansai-u.repo.nii.ac.jp/record/11528/files/KU-1100-20000000-11.pdf"},"version_id":"5f71a76a-cf25-4402-8cab-bf55105faaac"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Medical plastics","subitem_subject_scheme":"Other"},{"subitem_subject":"Silicon rubber","subitem_subject_scheme":"Other"},{"subitem_subject":"Catheters","subitem_subject_scheme":"Other"},{"subitem_subject":"Effluents","subitem_subject_scheme":"Other"},{"subitem_subject":"Electrospray ionization mass spectrometry (ESI-MS)","subitem_subject_scheme":"Other"},{"subitem_subject":"Poly(dimethyl siloxane)","subitem_subject_scheme":"Other"},{"subitem_subject":"Poly(ethylene glycol)","subitem_subject_scheme":"Other"},{"subitem_subject":"Poly(propylene glycol)","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析"}]},"item_type_id":"9","owner":"1","path":["1597"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-01-28"},"publish_date":"2012-01-28","publish_status":"0","recid":"11528","relation_version_is_last":true,"title":["医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:15:23.522230+00:00"}