<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-10T09:33:41Z</responseDate>
  <request identifier="oai:kansai-u.repo.nii.ac.jp:00011528" metadataPrefix="oai_dc" verb="GetRecord">https://kansai-u.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:kansai-u.repo.nii.ac.jp:00011528</identifier>
        <datestamp>2024-12-23T06:50:07Z</datestamp>
        <setSpec>528:1588:1595:1597</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>ESI-MS Analysis of Effluents from Medical Silicon Rubber</dc:title>
          <dc:title>医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析</dc:title>
          <dc:creator>荒川, 隆一</dc:creator>
          <dc:creator>26968</dc:creator>
          <dc:creator>Arakawa, Ryuichi</dc:creator>
          <dc:creator>00127177</dc:creator>
          <dc:creator>福尾, 剛志</dc:creator>
          <dc:creator>26969</dc:creator>
          <dc:creator>久保田, 直子</dc:creator>
          <dc:creator>26970</dc:creator>
          <dc:creator>田村, 正博</dc:creator>
          <dc:creator>26971</dc:creator>
          <dc:subject>Medical plastics</dc:subject>
          <dc:subject>Silicon rubber</dc:subject>
          <dc:subject>Catheters</dc:subject>
          <dc:subject>Effluents</dc:subject>
          <dc:subject>Electrospray ionization mass spectrometry (ESI-MS)</dc:subject>
          <dc:subject>Poly(dimethyl siloxane)</dc:subject>
          <dc:subject>Poly(ethylene glycol)</dc:subject>
          <dc:subject>Poly(propylene glycol)</dc:subject>
          <dc:description>The catheter tubes of medical silicon rubber were dipped in ethanol. The effluents were fractionated by thin-layer chromatography (TLC), and their fractions were analyzed by ion trap electrospray ionization mass spectrometry (ESI-MS). The ESI mass spectra resulting from the main TLC fraction, R1=0.5 showed that the effluents were determined to be poly(dimethyl siloxane) (8 to 20 mer) that is a main part of a silicon rubber. The spectra for the origin in TLC showed that poly(ethylene glycol) (4 to 10 mer and 14 to 18 mer) and poly- (propylene glycol) (19 to 36 mer) as an antistatic agent were identified.</dc:description>
          <dc:description>journal article</dc:description>
          <dc:publisher>Mass Spectrometry Society of Japan</dc:publisher>
          <dc:date>2000</dc:date>
          <dc:type>VoR</dc:type>
          <dc:format>application/pdf</dc:format>
          <dc:identifier>Journal of the Mass Spectrometry Society of Japan</dc:identifier>
          <dc:identifier>5</dc:identifier>
          <dc:identifier>48</dc:identifier>
          <dc:identifier>353</dc:identifier>
          <dc:identifier>356</dc:identifier>
          <dc:identifier>AA1254271X</dc:identifier>
          <dc:identifier>13408097</dc:identifier>
          <dc:identifier>https://kansai-u.repo.nii.ac.jp/record/11528/files/KU-1100-20000000-11.pdf</dc:identifier>
          <dc:identifier>http://hdl.handle.net/10112/5955</dc:identifier>
          <dc:identifier>https://kansai-u.repo.nii.ac.jp/records/11528</dc:identifier>
          <dc:language>jpn</dc:language>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
