WEKO3
アイテム
{"_buckets": {"deposit": "ff9bf407-5623-4e34-a9d7-3a64eca91e36"}, "_deposit": {"created_by": 1, "id": "11528", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "11528"}, "status": "published"}, "_oai": {"id": "oai:kansai-u.repo.nii.ac.jp:00011528", "sets": ["1597"]}, "author_link": ["26969", "26972", "26968", "26974", "26973", "26975", "26970", "26971"], "item_9_alternative_title_20": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "ESI-MS Analysis of Effluents from Medical Silicon Rubber"}]}, "item_9_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "356", "bibliographicPageStart": "353", "bibliographicVolumeNumber": "48", "bibliographic_titles": [{"bibliographic_title": "Journal of the Mass Spectrometry Society of Japan"}]}]}, "item_9_description_4": {"attribute_name": "概要", "attribute_value_mlt": [{"subitem_description": "The catheter tubes of medical silicon rubber were dipped in ethanol. The effluents were fractionated by thin-layer chromatography (TLC), and their fractions were analyzed by ion trap electrospray ionization mass spectrometry (ESI-MS). The ESI mass spectra resulting from the main TLC fraction, R1=0.5 showed that the effluents were determined to be poly(dimethyl siloxane) (8 to 20 mer) that is a main part of a silicon rubber. The spectra for the origin in TLC showed that poly(ethylene glycol) (4 to 10 mer and 14 to 18 mer) and poly- (propylene glycol) (19 to 36 mer) as an antistatic agent were identified.", "subitem_description_type": "Other"}]}, "item_9_description_42": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_description": "Journal Article", "subitem_description_type": "Other"}]}, "item_9_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "26972", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Arakawa, Ryuichi"}]}, {"nameIdentifiers": [{"nameIdentifier": "26973", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Fukuo, Tsuyoshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "26974", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kubota, Naoko"}]}, {"nameIdentifiers": [{"nameIdentifier": "26975", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tamura, Masahiro"}]}]}, "item_9_publisher_34": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Mass Spectrometry Society of Japan"}]}, "item_9_source_id_10": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA1254271X", "subitem_source_identifier_type": "NCID"}]}, "item_9_source_id_8": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13408097", "subitem_source_identifier_type": "ISSN"}]}, "item_9_text_35": {"attribute_name": "出版者(他言語)", "attribute_value_mlt": [{"subitem_text_value": "日本質量分析学会"}]}, "item_9_version_type_17": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "荒川, 隆一"}], "nameIdentifiers": [{"nameIdentifier": "26968", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福尾, 剛志"}], "nameIdentifiers": [{"nameIdentifier": "26969", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "久保田, 直子"}], "nameIdentifiers": [{"nameIdentifier": "26970", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田村, 正博"}], "nameIdentifiers": [{"nameIdentifier": "26971", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-05-23"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KU-1100-20000000-11.pdf", "filesize": [{"value": "391.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 391200.0, "url": {"label": "KU-1100-20000000-11.pdf", "url": "https://kansai-u.repo.nii.ac.jp/record/11528/files/KU-1100-20000000-11.pdf"}, "version_id": "5f71a76a-cf25-4402-8cab-bf55105faaac"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Medical plastics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Silicon rubber", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Catheters", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Effluents", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Electrospray ionization mass spectrometry (ESI-MS)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Poly(dimethyl siloxane)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Poly(ethylene glycol)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Poly(propylene glycol)", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析"}]}, "item_type_id": "9", "owner": "1", "path": ["1597"], "permalink_uri": "http://hdl.handle.net/10112/5955", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-01-28"}, "publish_date": "2012-01-28", "publish_status": "0", "recid": "11528", "relation": {}, "relation_version_is_last": true, "title": ["医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析"], "weko_shared_id": -1}
医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析
http://hdl.handle.net/10112/5955
http://hdl.handle.net/10112/5955e4c1ef8a-32f4-462e-adb0-11ba46141640
名前 / ファイル | ライセンス | アクション |
---|---|---|
KU-1100-20000000-11.pdf (391.2 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-01-28 | |||||
タイトル | ||||||
タイトル | 医療用シリコンゴムからの溶出物のエレクトロスプレー質量分析 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | ESI-MS Analysis of Effluents from Medical Silicon Rubber | |||||
著者 |
荒川, 隆一
× 荒川, 隆一× 福尾, 剛志× 久保田, 直子× 田村, 正博 |
|||||
著者別名 | ||||||
姓名 | Arakawa, Ryuichi | |||||
著者別名 | ||||||
姓名 | Fukuo, Tsuyoshi | |||||
著者別名 | ||||||
姓名 | Kubota, Naoko | |||||
著者別名 | ||||||
姓名 | Tamura, Masahiro | |||||
概要 | ||||||
内容記述タイプ | Other | |||||
内容記述 | The catheter tubes of medical silicon rubber were dipped in ethanol. The effluents were fractionated by thin-layer chromatography (TLC), and their fractions were analyzed by ion trap electrospray ionization mass spectrometry (ESI-MS). The ESI mass spectra resulting from the main TLC fraction, R1=0.5 showed that the effluents were determined to be poly(dimethyl siloxane) (8 to 20 mer) that is a main part of a silicon rubber. The spectra for the origin in TLC showed that poly(ethylene glycol) (4 to 10 mer and 14 to 18 mer) and poly- (propylene glycol) (19 to 36 mer) as an antistatic agent were identified. | |||||
書誌情報 |
Journal of the Mass Spectrometry Society of Japan 巻 48, 号 5, p. 353-356, 発行日 2000 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13408097 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA1254271X | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
出版者 | ||||||
出版者 | Mass Spectrometry Society of Japan | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Medical plastics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Silicon rubber | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Catheters | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Effluents | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Electrospray ionization mass spectrometry (ESI-MS) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Poly(dimethyl siloxane) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Poly(ethylene glycol) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Poly(propylene glycol) | |||||
出版者(他言語) | ||||||
日本質量分析学会 |